Comparison of Light Penetration of Continuous Wave 810 nm and Superpulsed 904 nm Wavelength Light in Anesthetized Rats

lightforce laser used on patient wrist
High-Intensity Laser Therapy
May 7, 2020
By Enovis Editorial Team

This study examines the 2012 publication by Joensen et al. Transmission through an anesthetized rat skin flap with a continuous wave 810 nm laser and a superpulsed 904 nm laser. The authors conclude that penetration through tissue of 810 nm wavelength light is greater than that of superpulsed 904 nm light. They suggest that the increase in intensity reported by Joensen et al. was due to insufficient warm-up of the superpulsed laser.

Download

About this study summary

This page summarizes Comparison of Light Penetration of Continuous Wave 810 nm and Superpulsed 904 nm Wavelength Light in Anesthetized Rats. The page gives the source as: Photomedicine and Laser Surgery. 2016; 34(9): 418-424. doi: 10.1089/pho.2016.4137. It was posted on Chattanooga Rehab on May 7, 2020, in the High-Intensity Laser Therapy category.

Chattanooga® is Enovis’ (NYSE: ENOV) signature rehabilitation brand, founded in 1947 in Chattanooga, Tennessee. Read more on the About Us page.

Who it is for

Researchers and clinicians who want to see how laser penetration through tissue is compared at two wavelengths and pulse modes.

What the summary says

  • The page describes this study as a response to a 2012 publication by Joensen et al. that examined transmission through an anesthetized rat skin flap with a continuous wave 810 nm laser and a superpulsed 904 nm laser.
  • The authors conclude that penetration through tissue of 810 nm light is greater than that of superpulsed 904 nm light.
  • They suggest that the increase in intensity reported by Joensen et al. was due to insufficient warm-up of the superpulsed laser.
  • This is an animal tissue study. The page links to a downloadable PDF.

What this page is not

It summarizes one published item and is not a treatment protocol. This page summarizes a published study. The findings and conclusions belong to the study authors, and the summary is not a substitute for reading the full paper or for your own clinical judgment. Neither DJO, LLC nor any of the Enovis companies dispense medical advice.

Related resources

Frequently asked questions

What is this page?

A summary of the study titled Comparison of Light Penetration of Continuous Wave 810 nm and Superpulsed 904 nm Wavelength Light in Anesthetized Rats, posted on Chattanooga Rehab on May 7, 2020.

Where was it published?

Photomedicine and Laser Surgery. 2016; 34(9): 418-424. doi: 10.1089/pho.2016.4137.

What does the summary cover?

The page describes this study as a response to a 2012 publication by Joensen et al. that examined transmission through an anesthetized rat skin flap with a continuous wave 810 nm laser and a superpulsed 904 nm laser.